IconHDPE Cable Duct
HDPE Cable Duct
Arrow Apollo PLB Duct Permanently Lubricated HDPE Ducts are produced on state of the art machinery by co-extrusion process.

Arrow Apollo PLB Duct PE Ducts are extruded from approved grade of virgin material as per national/international specifications and co-extruded with special lubricated material (compatible with base material) uniformly distributed in entire inner surface of duct providing a low friction smooth surface for High Speed Air Blowing or Drawing of Optical Fiber Cable.

ArrowApollo PLB Duct are manufactured using latest processing technology to meet performance requirements of national & international specifications.

ArrowApollo PLB Duct are manufactured as per TEC specification G/CDS-08/02,NOV.2004 & ISO STANDARDS.

ArrowApollo PLB Duct are available in ORANGE, YELLOW, RED, PURPLE, GREY, GREEN, BLUE & BLACK colours for easy identifications of cables installed.

ArrowApollo PLB Duct can withstand pressure of air blowing of cable (140 to 150 psi.) as well as soil pressure & traffic load. Cables can be removed and reblown number of times.

ArrowApollo PLB Duct are available in coils of 200,500 & 1000mtrs length thus reducing the number of joints in a network which enables to reduce the cost & time of installation. Other coil lengths & straight lengths are available as per customer's specification.

ArrowApollo PLB Duct are printed with indelible ink marking in every meter with progression measurement for accurate installation & measurement.

ArrowApollo PLB Duct Coils are provided with end cap to prevent dust, soil & insecticides entry into the duct till cable blowing.

ArrowAssociated Accessories & Tools

Arrow Plastic Coupler To join two duct lengths-air tight and water tight

Arrow End Plug To seal duct ends prior to the installation of the cable

Arrow Cable Sealing Plug To seal duct ends after insertion of the cable

Arrow End Cap Made of hard rubber, fitted on both ends of duct coil after manufacturing

Arrow Duct Cuter To cut duct cleanly and with square ends

Arrow C Spanner To tighten plastic coupler

ArrowTechnical Specifications

ArrowPLB HDPE Ducts Dimensions: (DOT & ISO), All Sizesi in mm

S. No. Duct Size (mm) Outer Dia (mm) Ovality (Max) (mm) Wall Thickness(mm)
1 32/26 32+0.3 1.3 2.8+0.4
2 40/33 40+0.4 1.4 3.3+0.4
3 50/42 50+0.5 1.4 3.7+0.6
4 * 63/55 63+0.6 1.5 3.6+0.6
5 * 75/65 75+0.7 1.6 4.3+0.7
6 * 90/79 90+0.9 1.8 5.1+0.8
7 * 110/96 110+1.0 2.2 6.3+1.0
Note: Sl.no. 4,5,6 & 7(* ) are not included in TEC Specification

ArrowPerformance Requirement

S. No. Test Unit Wall Thickness(mm) Standard Value
1 Tensile Strength N/mm² >20
2 Elongation % >500
3 Reversion % <+3
4 E S C R (As per ASTM D-1693) 96 Hours Sample should not crack during test period
5 Impact Strength Kg The duct shall not crack or split (At 10 Kg. Load)
6 Crush Resistance The Deflection with Load

The Deflection afterRecovery
%


%
< = 10


< = 2
7 Mandrel Test - The Mandrel shall be passed freely through a 5 mtr length of duct, when the duct is bent to a radius of 5 mtrs.
8 Oxidation Induction Test Minutes > 30
9 Internal Coefficient of Friction - Not More than 0.06
10 Melt Flow rate (at 5 kg, 190º C) gm/10 min 0.2 to 1.1
11 Density (Finish Product) gm/cc 0.940 To 0.958
12 Hydraulic Characteristics At temp 80º C.
- Test Duration Induced Stress
Type Test 165 Hrs 3.5 Mpa
Acceptance Test 48 Hrs 3.8 Mpa
- The Sample shall not show sign of localized swelling or leakage & shall not burst during the test period.
13 Ash Content % 0.3 Max